496383_sm01.mp4 (30.33 MB)

Supplementary Material for: Intracameral Air and Fibrin Glue for the Management of Late Bleb Leak following Glaucoma Surgery

Download (30.33 MB)
dataset
posted on 24.01.2019 by Hayat M.R., Mollah F.S., Kishore K.
Background and Objectives: To report a case of delayed-onset bleb-associated endophthalmitis (BAE) with bleb leak successfully managed with pars plana vitrectomy, intravitreal antibiotics, intracameral air, and fibrin glue. Patient and Methods: A 66-year-old pseudophakic female presented with BAE and bleb leak. A 25-gauge pars plana vitrectomy, cultures, and intravitreal antibiotics and steroid injections were performed. The infusion was switched to air filling the anterior chamber and bleb with air. Fibrin glue (Tisseel®) was applied over the leaking bleb. Results: BAE and bleb leak resolved with return of visual acuity to 20/25 and a functioning bleb with no recurrence of bleb leak after 1 year of follow-up. Conclusion: The combination of intracameral air and fibrin glue may have a role in the management of bleb leaks.