Supplementary Material for: A Novel Method for Tracking Neck Motions Using a Skin-Conformable Wireless Accelerometer: A Pilot Study

dataset
posted on 2024-04-10, 13:26 authored by Huang L., Chun K.S., Yu L., Lee J.Y., Soetikno A., Chen H., Jeong H., Barrett J., Martell K., Kang Y., Patel A.A., Xu S.
Introduction: Cervical spine disease is a leading cause of pain and disability. Degenerative conditions of the spine can result in neurologic compression of the cervical spinal cord or nerve roots and may be surgically treated with an anterior cervical discectomy and fusion (ACDF) in up to 137,000 people per year in the United States. A common sequelae of ACDF is reduced cervical range of motion (CROM) with patient-based complaints of stiffness and neck pain. Currently, tools for assessment of CROM are manual, subjective, and only intermittently utilized during doctor or physical therapy visits. We propose a skin-mountable acousto-mechanic sensor (ADvanced Acousto-Mechanic sensor; ADAM) as a tool for continuous neck motion monitoring in postoperative ACDF patients. We have developed and validated a machine learning neck motion classification algorithm to differentiate between eight neck motions (right/left rotation, right/left lateral bending, flexion, extension, retraction, protraction) in healthy normal subjects and patients. Methods: Sensor data from 12 healthy normal subjects and 5 patients were used to develop and validate a Convolutional Neural Network (CNN). Results: An average algorithm accuracy of 80.0 ± 3.8% was obtained for healthy normal subjects (94% for right rotation, 98% for left rotation, 65% for right lateral bending, 87% for left lateral bending, 89% for flexion, 77% for extension, 50% for retraction, 84% for protraction). An average accuracy of 67.5 ± 5.8% was obtained for patients. Discussion: ADAM, with our algorithm, may serve as a rehabilitation tool for neck motion monitoring in postoperative ACDF patients. Sensor-captured vital signs and other events (extubation, vocalization, physical therapy, walking) are potential metrics to be incorporated into our algorithm to offer more holistic monitoring of patients after cervical spine surgery.

History

Usage metrics

    Digital Biomarkers

    Categories

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC